3.2.3
[Transducer Setting] menu
Set up the HF and LF transducers on the [Transducer Setting] menu. The settings that
are entered on the initial setting menu are applied to the [Transducer Setting] menu.
To access the [Transducer Setting] menu, open the service menu referring to
section 3.2.1 and select [Transducer Setting] from the menu on the left-hand side of
the window.
The following display example is for the HF transducer. The menu items for the LF
transducer are same as the HF transducer.
Note: If a transducer is replaced with a different transducer, change the transducer
settings BEFORE replacing the transducer.
Menu item
[Connection]
[XDCR Select]
[Freq (Model)]
[Transducer]
[TX Power]
[Freq (Manual)]
××.××
Advanced Settings
HF
LF
Connection
Stabilization
XDCR Select
HF
LF
Freq(Model)
Mode
Transducer
Tests
TX Power
Service
Freq(Manual)
Shared Settings
Voltage
HF
Band Width
LF
Fish Size
HF
LF
IDENTI-FISH
HF
LF
Transducer Setting
HF
LF
Restore Default Settings
Set the presence of the transducer connection ([Connected]/[Not
Connected]). When [Connected] is selected, set up the following
menu items.
Select the setting method of the transducer.
• [TD-ID]: When a TD-ID transducer is connected.
• [Model]: Select the transducer model.
• [Manual]: Manually input the transducer information.
Note: For the [Model] and [Manual] setting, it may be necessary to
apply an offset to fish size (length) if the calculated and actual fish
sizes are different, to get accurate data for the fish size histogram.
For details of the [Fish Size] menu see the operator's manual.
Select the central frequency of the transducer (38, 50, 107 or 200
kHz). This menu item is enabled when [XDCR Select] is set to [Mod-
el]. If [TD-ID] is selected, the frequency is automatically entered.
Select the model number of the transducer. This menu item is en-
abled when [XDCR Select] is set to [Model]. If [TD-ID] is selected,
the model number is automatically entered.
The TX power of the transducer automatically appears according to
the model number. The setting is fixed. The value is shown only
when [XDCR Select] is set to [Model] or [TD-ID].
Manually set the frequency of the transducer (setting range: 15 to
200 kHz). This menu item is enabled when [XDCR Select] is set to
[Manual].
Transducer Setting : HF
Connected
Model
200
CM265LHG
OK
Description
3. INITIAL SETTINGS
Apply
Cancel
3-9