2. WIRING
Transducer cable
1. Remove the vinyl sheath by approx. 150 mm to expose the braided shield.
2. Pull the cores out from the braided shield, remove the aluminum tape and cut the
purple signal core.
Note: Be careful not to cut the four drain wires.
Braided shield
3. Wind the braided shield and drain wires around the vinyl sheath, then wind vinyl
tape around edge of the shield.
4. Remove the sheath by approx. 6 mm, then attach the terminal block connector.
How to connect wires to a terminal block connector
2-8
Vinyl sheath
Aluminum tape
25mm
25mm
Vinyl tape
Wind the braided shield and drain wires.
Clamp this part with the cable securing plate.
Press downward.
Terminal
opener
Terminal block
connector
Twist
150 mm
150 mm
Braided shield
Do NOT cut the drain wires.
Vinyl tape
Procedure
1. Twist the cores.
2. Press the terminal opener
downward.
3. Insert the wire in the hole.
4. Remove the terminal
opener.
5. Pull the wire to confirm
that it is secure.