No.
Selection of wiper output timing when
11
setting upper dead point stop
Setup of feed moving limit range
12
(+X direction)
Setup of feed moving limit range
13
(–X direction)
Setup of feed moving limit range
14
(+Y direction)
Setup of feed moving limit range
15
(–Y direction)
16
Selection of automatic
preparation at power on
17
Valid/Invalid selection of needle
bar stop holding mode
18
Selection of thread tension output
value while wiper output is active
19
Selection of feeding frame drive type
20
Setup of pneumatic presser lowering delayed time
(Disabled with motor presser selected)
21
Procedure setup for feeding frame operation at
automatic lifting and lowering of feeding frame control
Item
Setting range
Up position
Upper dead point
0 to 819mm
–819 to 0mm
0 to 819mm
–819 to 0mm
Ineffective
Effective
Ineffective
Effective
No output (with thread
trimming tension kept)
Maximum output
Motor presser
Pneumatic presser
0 to 1000ms
Full open,
full holding
Smallest
SS
HS
change-
2516
2516
able unit
1
+127
1
–127
1
+82
1
–82
10ms
1
Initial value
SL
SL
HL
HS
2516
2516
2516
3020
FU
+152
–152
+102
–102
100
0
HL
2516
FU
+127
–127
+82
–82