JUKI AMS-221EN Series Engineer's Manual page 96

Computer-controlled, cycle machine with input function
Table of Contents

Advertisement

• Level 2
No.
Selection of feeding frame lowering
1
speed at motor presser operation
Selection of feeding frame rising
2
speed at motor presser operation
Selection of pulse motor drive speed
3
at thread trimmer operation
Selection of temporary stop input
4
method
Selection of main motor drive speed
5
at thread trimmer operation
6
Valid/Invalid selection of jump feed
control at thread trimmer operation
Selection of needle hole guide diameter
7
at controlling thread trimming jump feed
Valid/Invalid selection of thread
8
trimmer device driving
9
Setup of output time of magnet wiper on
10
Setup of delay time of magnet wiper off
Item
Setting range
100 to 1500pps
100 to 3000pps
100 to 1500pps
Ineffective
Effective
Thread trimming with
temporary stop switch
or start with start pedal
after temporary stop
400sti/min
800sti/min
Ineffective
Effective
1.6 to 4.0mm
Normal operation
Prohibited to use
10 to 500ms
10 to 500ms
Smallest
change-
SS
HS
able unit
2516
2516
10pps
10pps
10pps
0.2mm
10ms
10ms
Initial value
SL
SL
HL
HS
2516
2516
2516
3020
FU
1500
3000
1000
S type : 1.6/H type : 2.0
50
80
HL
2516
FU

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ams-221enssAms-221enhsAms-221enhlAms-221ensl

Table of Contents