2. Output terminal setup
Output No.
Contents
0
Nil
For the actuator
1
Feeding frame 1
2
Feeding frame 2
3
Feeding frame 3
4
Feeding frame 4
5
(Intermediate presser)
6
Air OFF
7
Reverse shaft
8
Third thread tension
9
Needle cooler
For pattern data outputs
33
External output 0
34
External output 1
35
External output 2
36
External output 3
37
External output 4
38
External output 5
39
External output 6
40
External output 7
41
External output 8
42
External output 9
43
External output 10
44
External output 11
45
External output 12
46
External output 13
47
External output 14
48
External output 15
Status of sewing machine head
49
Needle upper position
50
Needle lower position
51
Needle upper dead point position
52
Needle lower dead point position
53
Thread trimming signal
54
During rotation
55
Sewing machine brake signal
56
Void
Status of sewing machine unit
57
Status of setup
58
Status of READY operation
59
READY status
60
Sewing status
61
During sewing
62
Sewing machine in driving
63
Resetting to the sewing start point
64
Sewing being stopped on the way
65
Stop with sewing error display
66
Temporary stop of sewing
67
XY feeding operation
68
Origin reset
69
Presser lowering status
No output
Feeding frame right lifting
Feeding frame left lifting
(Feeding frame right 2-stage stroke)
Feeding frame left 2-stage stroke
(Signal output)
Air is OFF when the power supply is OFF.
Reverse shaft setting side
Third thread tension closed
Needle cooler air output
Reverse signal output with the External Output 0 command of the pattern data
Reverse signal output with the External Output 1 command of the pattern data
Reverse signal output with the External Output 2 command of the pattern data
Reverse signal output with the External Output 3 command of the pattern data
Reverse signal output with the External Output 4 command of the pattern data
Reverse signal output with the External Output 5 command of the pattern data
Reverse signal output with the External Output 6 command of the pattern data
Reverse signal output with the External Output 7 command of the pattern data
Reverse signal output with the External Output 8 command of the pattern data
Reverse signal output with the External Output 9 command of the pattern data
Reverse signal output with the External Output 10 command of the pattern data
Reverse signal output with the External Output 11 command of the pattern data
Reverse signal output with the External Output 12 command of the pattern data
Reverse signal output with the External Output 13 command of the pattern data
Reverse signal output with the External Output 14 command of the pattern data
Reverse signal output with the External Output 15 command of the pattern data
Upper stop position
(Internal signal)
Reverse rotation needle lifting position 5 to 30°
Lower stop position
During thread trimming stop (not used) ON beneath the needle shortly before stoppage →
In the middle of sewing machine driving ON at the start of rotation → OFF at +120ms above
During sewing machine stop
In the setup condition
Ready key → Origin retrieval → Moving to the sewing start point and thereafter
In the ready condition
From the start of sewing to the feeding frame lifting after moving to the sewing start point.
Feed forward included.
From the start of sewing to the end of pattern data. Jump feed included.
In the middle of sewing machine head driving during sewing. Bobbin and needle lifting reset
not included.
From the end of pattern data to the reset of the sewing start point.
Stopped with a midway stop command of the pattern data.
Error display being presented because of error stop during sewing.
Error stop during sewing or temporary stop after the promotion of stitching due to pattern
check, etc.
Jump feed during sewing, pattern check, feed forward/return motion, and others.
Origin reset key → Reset to the sewing start point
Presser lowering key → Presser lowering status
– 109 –
Explanation
40 to 62°
(Always ON shortly after Power ON)
80 to 123° (Always OFF shortly after Power ON)
(Always OFF shortly after Power ON)
209 to 239° (Always OFF shortly after Power ON)
OFF at +70ms above the needle
the needle
ON beneath the needle shortly before stoppage →
OFF at +120ms above the needle

Hide quick links: