JUKI AMS-221EN Series Engineer's Manual page 164

Computer-controlled, cycle machine with input function
Table of Contents

Advertisement

No.
Pictograph
Sensor applications
No.
Sensor data
11
AU DET sensor
12
AD DET sensor
13
D DET sensor
14
U DET sensor
15
TG sensor
16
P DETsensor
17
S DET sensor
Contents of sensor
External input 6
External input 7
External input 8
External input 9
External input 10
External input 11
For needle bar reverse revolution (5° to 30°)
For needle bar DOWN stop (209° to 239°)
Not used (For thread cutting timing of former models)
For needle bar UP stop (40° to 62°)
ON-OFF by dividing one turn of the main shaft into 45 portions.
For feed timing
Not used. (ON-OFF by dividing one turn of the main shaft into 2 portions.)
No.
Pictograph
Applications
– 160 –
Contents of sensor
External input 12
External input 13
External input 14
External input 15
External input 16