JUKI AMS-221EN Series Engineer's Manual page 102

Computer-controlled, cycle machine with input function
Table of Contents

Advertisement

No.
Common data setting of thread
58
tension standard value
Common data setting for height standard
59
value of intermediate presser
Selection of display screen when
60
shifting sewing mode.
Setting of changing amount of thread
61
tension
Selection of Valid/Invalid of linear
62
feed button
Selection of readout code type
63
of barcode
64
Valid/Invalid selection of machine
head safety switch
Main shaft speed control during
65
XY feed operation
Item
Setting range
0 to 200
0 to 3.5
Sewing screen
Thread tension screen
2 to 5
Ineffective
Effective
CODE39
All codes
Effective
Ineffective
Auto deceleration,
manual acceleration
Auto deceleration,
auto acceleration
Auto deceleration,
imit cancellation after
completion of sewing
Auto deceleration,
and limit cancellation
No automatic
deceleration
Smallest
SS
HS
change-
2516
2516
able unit
1
0.1
1
Initial value
SL
SL
HL
HS
2516
2516
2516
3020
FU
40
2.0
5
HL
2516
FU