Pci Led Lights Up; Sp Led Lights Up - Avaya S8800 Maintaining

2u server for message networking
Hide thumbs Also See for S8800:
Table of Contents

Advertisement

Light path diagnostics
Troubleshooting steps
Procedure
1. Check the power supply LEDs for an error indication. For example, AC LED and DC LED do
not both light up.
2. Make sure that the power supplies are seated correctly.
3. Remove one of the power supplies to isolate the failed power supply.
4. Replace the failed power supply.
Related Links
Power supply LEDs

PCI LED lights up

The PCI LED on the light path diagnostics panel lights up when an error occurs on a PCI bus or on
the system board. An additional LED lights up next to a failing PCI slot.
Troubleshooting steps
Procedure
1. Check the LEDs on the PCI slots to identify the component that caused the error.
2. If you have a monitor, check the system error log for information about the error.
3. If you cannot isolate the failing PCIe card by using the LEDs and the information in the
system error log, remove one card at a time from the failing PCI bus. Restart the server after
each card is removed.
4. Reseat the failing PCIe card.
5. Replace the server.

SP LED lights up

The SP LED on the light path diagnostics panel lights up when an error occurs on the service
processor.
Troubleshooting steps
Procedure
1. Disconnect the server from the power source, and then reconnect the server to the power
source and restart the server.
2. Report this error to your service provider for possible server replacement.
Maintaining the Avaya S8800 2U Server for Message Networking
54
on page 61
Comments? infodev@avaya.com
May 2014

Advertisement

Table of Contents
loading

Table of Contents