LED indicators
See the Maintenance Alarms for Avaya Communication Manager 3.0, Media Gateways and
Servers (03-300430) for detailed alarm and LED descriptions. If a maintenance object begins to
fail some periodic tests, the media server generates an alarm.
The media server identifies three levels of alarms:
1. Major Alarms—Failures that cause critical degradation of service and require immediate
attention.
2. Minor Alarms—Failures that cause some degradation of service, but do not cause a critical
portion of the configuration to be inoperable. This condition requires action, but its
consequences are not immediate. Problems might be impaired service to a few trunks or
stations or interfering with one feature across the entire configuration.
3. Warning Alarms—Failures that cause no significant degradation of service or failures in
equipment external to the configuration. Warning alarms are not reported to the attendant
console or INADS.
Alarms are communicated to users and technicians by entries in the alarm and system logs and
the lighting of LEDs located on the media server.
More detailed information is available here for:
S8700 Media Server LEDs
●
S8710 Media Server LEDs
●
Avaya Ethernet switch LEDs
●
Uninterruptible power supply LEDs
●
IPSI LEDs
●
on page 86
on page 88
on page 90
on page 91
on page 91
LED indicators
Issue 4.1 June 2005
85