Avaya S8800 Maintaining page 76

2u server for message networking
Hide thumbs Also See for S8800:
Table of Contents

Advertisement

Troubleshooting hard disk drive, power, or memory problems
Troubleshooting steps
About this task
Procedure
1. Reseat the DIMMs.
2. Restart the server.
3. Remove the lowest numbered DIMM pair of those that are identified and replace it with an
identical pair of known good DIMMs. Then, restart the server.
4. Repeat Step 3 as necessary. If the failures continue after all identified pairs are replaced, go
to step 8.
5. Return the removed DIMMs, one pair at a time, to their original connectors. Restart the
server after each pair, until a pair fails.
6. Replace each DIMM in the failed pair with an identical known good DIMM. Restart the server
after each DIMM.
7. Replace the failed DIMM. Repeat steps 5 and 6 until you have tested all removed DIMMs.
8. Replace the lowest numbered DIMM pair of those identified. Then, restart the server.
9. Repeat Step 8 as necessary.
Maintaining the Avaya S8800 2U Server for Message Networking
76
Comments? infodev@avaya.com
May 2014

Advertisement

Table of Contents
loading

Table of Contents