Enlargement

Stop
1
0
Start
1139D032CA
AUTO
1
Start
1139D039CA
AUTO
1139D041CA
Start
Panel reset
1139D019CA
1. After the leading edge registration in the full size
mode has been adjusted, make two single copies in
an enlargement mode (200 %) and check for leading
edge registration on the second copy.
(If the enlargement leading edge registration meets
the requirement, go to "Adjustment of Reduction
Leading Edge Registration.")
2. If the registration does not meet the requirement, go to
the control panel and press the Stop Key, Multi-Copy
Key "0," Stop Key, and Multi-Copy Key "1," in that
order, to set the copier into a state ready to enter a
particular Tech. Rep. Mode.
3. Press the Stop Key and then press the Start Key to
set the copier into the Adjust Mode. (At this time, the
Magnification Ratio Indicator shows "A.")
4. Press Multi-Copy Key "1" twice and press the Start
Key. (Then, the Magnification Ratio Indicator shows "A
11" and the Multi-Copy Display, the current setting
value.)
5. Press the Clear Key to clear the current setting value.
6. With the old setting value used as reference, enter the
new setting value using the appropriate Multi-Copy
Keys.
NOTE
C
If dimension A on the copy is smaller than 37.0 mm,
decrease the setting value.
If dimension A on the copy is greater than 43.0 mm,
increase the setting value.
7. Press the Start Key to validate the new setting.
8. Press the Panel Reset Key twice (or turn OFF the
Power Switch) to return the copier back to the normal
mode.
9. Make two single copies and check for leading edge
registration on the second copy. (If it does not meet
the requirement, perform steps 2 through 9 again.)
D-59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents