4. Go to the rear of the copier and unplug the connector
of Unexposed Areas/Edge Erase Lamp.
5. Remove the Imaging Unit.
6. Remove one screw to remove the Unexposed
Areas/Edge Erase Lamp.
NOTE
When removing the Erase Lamp, use care not to lose
the pressure spring in the rear.
7. Using a brush or a soft cloth dampened with alcohol,
clean the Erase Lamp.
NOTE
After the Erase Lamp has been cleaned, make the
"Adjustment of the Unexposed Areas/Edge Erase
Lamp Position." See p. D-64.