Original Size Detection Failure - Minolta EP1080 Service Manual

Hide thumbs Also See for EP1080:
Table of Contents

Advertisement

13-2. Original Size Detection Failure

An original size detection failure (C0F02, C0FE1 to C0FFF) is detected
under any of the following timings.
C0F02: Original Size Detection Error
1) In F7 operation
a) The Busy signal does not go LOW within approx. 800 msec. after the
Initial signal has gone LOW.
b) The Busy signal does not go LOW within approx. 200 msec. after
condition a) above has been confirmed.
c) The Busy signal does not go HIGH within approx. 4,000 msec. after
conditions a) and b) above have been confirmed.
Initial Signal
Busy Signal
2) In normal operation
a) The Busy signal remains HIGH or LOW for approx. 500 msec. or
longer.
b) The normal data is undefined.
Busy Signal
C0FE1 to C0FFF: Original Size Detecting Sensor Failure
During normal operation, UN2 transmits a sensor error code corresponding
to any malfunction code from C0FE1 to C0FFF.
Approx. 200
Approx. 800msec.
msec.
Approx. 70
Approx. 70
msec
msec
M-49
Approx. 4,000msec.
1139T55MCA
Approx. 500 msec. or more
1139T56MCA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents