(2) Cleaning of the Main Erase Lamp
(3) Cleaning of the Unexposed Areas/Edge Erase Lamp
1. Go to the rear of the copier and unplug the connector
of the Main Erase Lamp.
2. Remove the Imaging Unit.
3. Pull out the Toner Bottle Holder to the front.
4. Remove one screw to remove the Main Erase Lamp.
5. Using a brush or a soft cloth dampened with alcohol,
clean the Erase Lamp.
NOTE
Do not touch the Lamp with bare hands.
1. Unplug six connectors from the lower part of Main
Control Board PWB-A.
2. Remove one screw to remove PWB-A.
3. Insert PWB-A into the copier to secure it.
D-31