Cleaning of the PC Drum Paper Separator Fingers

Cleaning of the Ds Positioning Collars

Cleaning of the Paper Dust Remover

Replacement of the Toner Antispill Mylar

11. Using a soft cloth dampened with alcohol, wipe clean
the Paper Separator Fingers.
12. Using a soft cloth dampened with alcohol, wipe clean
the Ds Positioning Collars.
13. Remove two screws and two compression coil springs
to remove the Synchronizing Roller Unit.
NOTE
When removing the Synchronizing Roller Unit, use
care not to lose the compression coil springs. At
reinstallation, fit the close-coiled end of the springs to
the bosses on the Imaging Unit.
14. Remove the Synchronizing Roller.
15. Using a brush, whisk the dust and dirt off the Filter.
16. Remove two screws to remove the Bias Seal.
(No Bias Seals are mounted in the copiers for the
U.S.A., Canada, and Europe.)
17. Remove two screws to remove the Toner Antispill
Mylar and replace the Mylar.
D-29