Table 101-1. Soneplex Broadband System (V5) Specifications, continued
PARAMETER
A2 RLX Module
Frame Format
Frequency
Input Signal Level
Line Code
Output Line Buildout Settings
Output Signal Range
Span Power
Version B RLX / RLXIOR Modules
Frame Format
Frequency
Input Signal Level
Line Code
Output Signal LBO Settings
Output Signal Range
Span Power
Streaker Module
Internal Batteries
Jack Type
System Input Voltage Range
TAU Module
DS1 Jack Access Jack Type
Electrical Interface
Impedance
Line Code
Line Rate
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
SPECIFICATION
SF, ESF, SLC96, and unframed
1.544 Mbps ± 200 bps (130 ppm)
0 dB to –33 dB
AMI or B8ZS
0.0, 7.5, 15.0, and 22.5 dB
Up to 3,000 feet (914.4 meters)
60 mA, –140 VDC max.
SF, ESF, SLC96 and unframed
1.544 Mbps ± 130 ppm
0 dB to –33 dB
AMI or B8ZS
0.0, 7.5, 15.0 and 22.5 dB
Up to 3,000 feet (914.4 meters)
over 22 AWG wire
60 mA, ±140 VDC maximum
4 AAA 1.5 volt (6 VDC)
Bantam
42.5 to
56.5 VDC
48 VDC nominal
Bantam
Bipolar
100 ohms nominal
AMI or B8ZS
1.544 Mbps ± 130 ppm max.
TAD-101
Page 5 of 9
REMARKS
Clock recovery range for loop
timing.
Up to 6,000 feet (1,828.8 meters)
with ideal cable conditions.
Up to 7 or 14 watts
Clock recovery range for loop
timing
Up to 6,000 feet (1,828.8
meters) depending on cable
characteristics
Up to 8 or 16 watts
Mounted on PCB
Controlled by front panel switch
(continued)
© 2000, ADC Telecommunications, Inc.