ADC Soneplex Broadband System Operation And Maintenance Manual page 184

Adc broadband system operation and maintenance manual
Table of Contents

Advertisement

STATUS FIELD: MODULE
DS1 Loopback
DS1 LOS
DS1 Line Code
DS1 Frame Format
Loop Reversal
HSKP1/HSKP2
PWR1/PWR2
STATUS FIELD: HDSL LOOPS
(HDSL) Start-Up IP
Tip-Ring (T/R) Reversal
SNR (Thresh) Exceeded
BER (Thresh) Exceeded
Pulse Attn (dB)
SNR (margin dB)
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
Table 548-2. HLX and HRX Status Field Displays
DISPLAY
ACTIVE,
INACTIVE
YES, NO
AMI, B8ZS, AUTO,
N/A
UNFRAMED,
Ft ONLY,
ESF,
SF, N/A
AUTO
YES, NO, N/A
YES, NO, N/A
YES, NO, N/A
DISPLAY
YES, NO, N/A
NRM, DIS, LSW
YES, NO, N/A
YES, NO, N/A
YES, NO, N/A
Range of +1 to +40
Range of –10 to +30
DESCRIPTION
A loopback is active or has been deactivated at
the HLXC, HRX, or HLXR.
A loss of signal has occurred at the HLXC, HRX,
or HLXR.
See DLP-531 for descriptions of related HLX
configuration fields.
See DLP-531 for descriptions of related HLX
configuration fields.
A loop reversal has occurred at the HLXC, HRX,
or HLXR.
Housekeeping alarms 1 and/or 2 have occurred at
the HLXC, HRX, or HLXR.
Power alarms 1 and/or 2 have occurred at the
HLXC, HRX, or HLXR.
DESCRIPTION
MPU5.2 software or later: no HRXs or MPU 5.1
software.
MPU 5.2 software or later: Normal, Disabled, or
Loss of Synch Word at Loop 1 or Loop 2 at the
HLXC or HLXR.
See DLP-531 for descriptions of related HLX
configuration fields.
See DLP-531 for descriptions of related HLX
configuration fields.
See DLP-531 for descriptions of related HLX
configuration fields.
See DLP-531 for descriptions of related HLX
configuration fields.
© 2000, ADC Telecommunications, Inc.