ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
DLP-533
Page 4 of 5
FIELD
TYPE
Span Power
Toggle
Setting**
Pulse
Toggle
Equalization**
LBO Setting**
Toggle
Programmable
Toggle
Loopback
NID Loopback**
Toggle
*Note: The RLXIOR configuration field default values shown in this manual are valid for systems with an MPU installed.
**Note: Although unit switch settings (Pulse Equalization, Span Power, NID Loopback, and LBO) are shown at the bottom of the
configuration screen, none of the displays are meaningful for the RLXIOR. First, there are no on-board switches for Pulse
Equalization, NID Loopback, and LBO. In addition, although the RLXIOR has an on-board Line Power switch, the Span Power
unit switch setting display is locked at "DISABLED".
2-112
© 2000, ADC Telecommunications, Inc.
Table 533-1. RLXIOR Configuration Fields, continued
OPTIONS
UNIT SWITCH
Stops span power on the RLXIOR.
ENABLED
Enables span power using the on-board
switch settings (–130V or ±130V). The
default switch setting is –130V.
DISABLED
Stops span power on the RLXIOR.
UNIT SWITCH
Selecting this option on the RLXIOR
creates a setting of 0–133 ft.
0–133 ft., 133–266 ft.,
The DS1 signal output provides standard
266–399 ft., 399–533 ft.,
DSX signal levels which can be
or 533–655 ft.
compensated for various distances.
UNIT SWITCH
Selecting this option on the RLXIOR
creates a setting of 0.0 dB.
0.0 dB, 7.5 dB, 15.0 dB,
Sets the LBO in decibels.
or 22.5 dB
ENABLED
Enables response to programmable
loopback codes.
DISABLED
Disables response to programmable
loopback codes.
UNIT SWITCH
Disables loop-up response to NID arming
code. The loopback armed state transitions
to "Armed" when the NID arming code is
received.
ENABLED
Enables response to NID loopback codes.
DISABLED
Disables loop-up response to NID arming
code. The loopback armed state transitions
to "Armed" when the NID arming code is
received.
DESCRIPTION
ENABLED
UNIT SWITCH (Loop
Extender chassis only)
NOT APPL (locked field
in Broadband chassis
only)
UNIT SWITCH
DISABLED
ENABLED
DEFAULT*
(continued)