ADC Soneplex Broadband System Operation And Maintenance Manual page 121

Adc broadband system operation and maintenance manual
Table of Contents

Advertisement

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
DLP-530
Page 3 of 3
FIELD
TYPE
T2 Service State
Toggle
BER Alarm
Toggle
Threshold
BER Switch
Toggle
Threshold
Provision
Toggle
(set for each T1)
T1 Service State
Toggle
Line Code
Toggle
(set for each T1)
Circuit Identifier
Input
(set for each T1)
Remote Pulse
Toggle
Equalization
Remote Frame
Fixed
Format
Remote PPS (Path
Fixed
Protection Switch)
Threshold
T2 Service State
Toggle
T1 Service State (set
Toggle
for each T1)
2-98
© 2000, ADC Telecommunications, Inc.
Table 530-1. ODS2 Configuration Fields, continued
OPTIONS
Leave this field at OOS at this time to avoid undesirable reporting of alarms.
Select IS after completing the remaining configurations.
Set to OFF or set between
The average Bit Error Ratios of both the
10 –6 and 10 –10
incoming optical signals are monitored by the
ODS2. By monitoring BERs, the ODS2 is
capable of triggering a minor alarm when any of
the monitored signals degrades below the BER
threshold level.
Set between 10 –4 and 10 –
This sets the threshold at which the APS will be
10
executed.
YES
Brings up T1 default settings and allows
configuration changes.
NO
Facility not provisioned.
Leave this field at OOS at this time to avoid undesirable reporting of alarms.
Select IS after completing the remaining configurations.
AMI
Alternate Mark Inversion
B8ZS
Bipolar Eight-Zero Substitution
Enter up to 20 characters
Use alphanumeric characters; embedded
or leave blank.
hyphens are allowed.
0–133 ft., 133–226 ft.,
The DS1 signal output provides standard DSX
226–399 ft., 399–533 ft.,
signal levels which can be compensated for at
533–655 ft., or NOT
various distances (i.e., cable length).
APPL.
Locked at NOT APPL.
Locked at NOT APPL.
IS (In-Service)
Places facility in service and allows T2 alarm
reporting by the MPU.
OOS (Out-Of-Service)
Removes facility from service and stops T2
alarm reporting by the MPU.
IS (In-Service)
Places facility in service and allows T1 alarm
reporting by the MPU.
OOS (Out-Of-Service)
Removes facility from service and stops T1
alarm reporting by the MPU.
DESCRIPTION
DEFAULT
OOS
10 –8
10 –6
NO
OOS
AMI
None
0–133 ft.
NOT APPL
NOT APPL
OOS
OOS