ADC Soneplex Broadband System Operation And Maintenance Manual page 141

Adc broadband system operation and maintenance manual
Table of Contents

Advertisement

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
DLP-534
Page 5 of 6
FIELD
TYPE
NID Loopback*†
Toggle
Loopback Activation
Input
Code
Loopback Deactivate
Input
Code
Lpbk Timeout
Input
Disable Code
Loopback Timeout
Input
Period
Network Keep Alive
Toggle
*Note: Unit switch settings (Pulse Equalization, Span Power, NID, and LBO) are shown on the bottom of the configuration screen.
†Note: The UNIT SWITCH option appears on screen for both RLX types, but is only functional for Version A.
2-118
© 2000, ADC Telecommunications, Inc.
Table 534-1. RLX Configuration Fields, continued
OPTIONS
UNIT SWITCH
Selects NID setting (either enabled [default]
or disabled) on the Version A RLX. When
the Version A is provisioned to function
like an NID, it supports inband and out-of-
band loopback codes.
ENABLE
Enables response to NID loopback codes
and overrides hardware configuration
settings.
DISABLE
Disables response to NID loopback codes
and overrides hardware configuration
settings.
16 binary characters
These codes can be set to any 16-bit binary
(0's and 1's) must be
value except: all 0s, all 1s, or a value that is
entered.
already used in another 16-bit code. The
signal is sent inband. RLX units go to
loopup state when they are in an armed
state. Loopup is activated for selected units.
Detection time is 3 secs.
The signal is sent inband. Units in loopup
state go back to armed state. Detection time
is 5 secs.
This disables the loopup time-out. Active
loopbacks stay up until deactivation or
disarm code is received. Detection time is 3
secs.
Enter a number from 0
This represents the minutes the loopback
to 255
remains in effect before reverting to the
non-loopback state. Setting the loopback
time out period to 0 disables the time out
feature.
AIS
If the system detects a LOS (Loss of Signal)
from the customer, an AIS is sent to the
network.
DS1 CUTOFF
If the system detects a LOS from the
customer, the signal is cut off and no signal
is transmitted to the network.
DESCRIPTION
Version A only:
UNIT SWITCH
Version B only:
DISABLE
1101 0011 1101 0011
1001 0011 1001 0011
1101 0101 1101 0110
30 minutes
AIS
DEFAULT
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents