ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
DLP-556
Page 1 of 3
Summary: This procedure provides instructions for assigning thresholds for each DS1 in the
Soneplex Broadband system. You can also view or edit the DS1 Performance Monitoring
configuration for each DS1 in the Soneplex Broadband system from this screen. Not all modules
support Performance Monitoring.
Note: A "toggle" field type means the user can press the space bar to view and select the
next option that is described; or the user can press the "R" key to view and select the
previous option. An "input" field type means the user must type an entry in the field
according to the parameters described. A "fixed" field is locked, and cannot be changed by
the user.
Note: Edits can be made in the configuration database in one of two ways: 1) If the
complete field is highlighted, use the space bar to toggle forward or the "R" key to
reverse toggle through the options for that field. 2) If only the first space or the field is
highlighted, type in the data that applies to that field.
Note: Edits to the configuration database can be saved after each change in one of two
ways: 1) Press an arrow key and then Enter or Return once; or 2) Press Enter or Return
twice after all selections and entries are made in the screen but before leaving the screen.
If the entries have been accepted, a message "Configuration Successful... Press Any Key
To Continue" appears on the screen.
Note: Press CONTROL-A for help information on moving around and editing fields.
1. Use the arrow keys to select Performance Monitoring from the Main Menu. Press Enter or
Return. A Performance Monitoring menu appears.
2. Use the arrow keys to select DS1 PM Configuration from the PM Configuration menu.
Press Enter or Return. A DS1 PM Configuration screen is shown in
3. Move to the Group toggle field. Select group number 1, 2, 3, 4, 5, 6, or 7.
4. Move to the Slot toggle field. Select slot number 1, 2, 3, or 4.
Reference:
TAD-106
5. Move to the Mon Type Threshold toggle fields. Enter the value for each field that you
wish to change based on ranges and default values for each Mon Type listed in
Table
556-1. Ranges are also listed at the bottom of the DS1 PM Configuration screen.
Reference:
TAP-102
2-180
© 2000, ADC Telecommunications, Inc.
DS1 PM CONFIGURATION
Access Identifier
Performance Monitoring Reports Description
Figure
556-1.