ADC Soneplex Broadband System Operation And Maintenance Manual page 272

Adc broadband system operation and maintenance manual
Table of Contents

Advertisement

Summary: This TAD shows technical specifications for the Soneplex Broadband system with
MPU Version 5 software in
Power),
Table 101-3
(DLX Power),
E HLXC Power),
Table 101-6
(Version B RLX / RLXIOR Power).
Table 101-1. Soneplex Broadband System (V5) Specifications
PARAMETER
Dimensions
Chassis (H × W × D)
Environment
Operating Relative Humidity
Operating Temperature
Storage Temperature
Power
Input Voltage Range
Consumption (–48 VDC):
APU
MPU
DS3 MUX
DLX
C1 HLXC
Version D and later HLXCs
B1 HLXR
Version D and later HLXRs,
HLXR 3192
ODS2
A2 RLX
Version B RLX / RLXIOR
TAU
RTAU
Maximum Power
ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
SPECIFICATIONS
Table 101-1
(System Specifications),
Table 101-4
(C1 HLXC Power),
(ODS2 Power),
Table 101-7
SPECIFICATION
10 × 21.5 × 12 inches
(25.4 × 54.6 × 30.5 cm)
5% to 95%
–40°F to 149°F (–40°C to 65°C)
–40°F to 158°F (–40°C to 70°C)
–42.5 to –56.5 VDC
7.5 watts maximum
5 watts maximum
See
Table 101-2
See
Table 101-3
See
Table 101-4
See
Table 101-5
9.9 watts
8.3 watts
9 watts
4 watts
See
Table 101-6
See
Table 101-7
See
Table 101-8
2 watts maximum
8.2 watts maximum
Determined by configuration
Table 101-2
(DS3 MUX
Table 101-5
(Version D and
(A2 RLX Power), and
Table 101-8
REMARKS
No condensation
A and B feed
Per module
Per module
Simplex current enabled
Simplex current disabled
Simplex power enabled (D1, D2,
D2A-SP, D3, D3A, D3B HLXRs
only)
Simplex power disabled (D2A,
D4, D4A, D4B, and Version E
HLXRs; and HLXR 3192 only)
© 2000, ADC Telecommunications, Inc.
TAD-101
Page 1 of 9
(continued)
2-249