ADC Soneplex Broadband System Operation And Maintenance Manual page 259

Adc broadband system operation and maintenance manual
Table of Contents

Advertisement

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
DLP-573
Page 5 of 6
Table 573-1. HLX Loopback Configuration Fields, continued
FIELD
TYPE
HLXR NID Loopback
Toggle
HLXR Activation
Input
Code
("Activation Code" is
equivalent to
"Programmable
Code.")
HLXR Programmable
Toggle
Lpbk
One HRX in system
Input
only: HRX or HRX1
Activation Code
("Activation Code" is
equivalent to
"Programmable
Code.")
2-236
© 2000, ADC Telecommunications, Inc.
OPTIONS
DESCRIPTION
UNIT SWITCH
Version E HLXR only: Selects
NID setting (enabled) for the
HLXR.
Version D or earlier HLXR:
Selects NID setting (either enabled
[default] or disabled) on the HLXR.
When the HLXR is provisioned to
function like an NID, it supports
inband and out-of-band loopback
codes.
ENABLED
Enables response to NID loopback
codes and overrides hardware
configuration settings.
DISABLED
Disables response to NID loopback
codes and overrides hardware
configuration settings.
16 binary characters (0's
16-bit codes can be programmed to
and 1's) must be entered.
any 16-bit binary value except: all 0s,
all 1s, or a value that is already used
in another 16-bit code. The signal is
sent inband. HDSL units go to
loopup state when they are in armed
state. Loopup is activated for selected
units. Detection time is 3 secs.
ENABLED
Enables response to programmable
loopback codes and overrides
hardware configuration settings.
DISABLED
Disables response to programmable
loopback codes and overrides
hardware configuration settings.
16 binary characters (0's
16-bit codes can be programmed to
and 1's) must be entered.
any 16-bit binary value except: all 0s,
all 1s, or a value that is already used
in another 16-bit code. The signal is
sent inband. HDSL units go to
loopup state when they are in armed
state. Loopup is activated for selected
units. Detection time is 3 secs.
DEFAULT
MPU V5.1:
UNIT SWITCH
MPU V5.2:
ENABLED
MPU V5.1:
1100 0111 0100 0010
MPU V5.2:
1100 0111 0101 0100
DISABLED
1100 0111 0100 0001
No HRX: NOT APPL
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents