ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
DLP-532
Page 1 of 3
Summary: This procedure provides instructions for establishing initial configuration of DLX
module(s) or view and/or edit the configurations for each DLX module in the Soneplex
Broadband system. Equip, provision, assign thresholds as required, and assign service state.
Note: A "toggle" field type means the user can press the space bar to view and select the
next option that is described; or the user can press the "R" key to view and select the
previous option. An "input" field type means the user must type an entry in the field
according to the parameters described. A "fixed" field is locked, and cannot be changed
by the user.
Note: Edits can be made in the configuration database in one of two ways: 1) If the
complete field is highlighted, use the space bar to toggle forward or the "R" key to
reverse toggle through the options for that field. 2) If only the first space or the field is
highlighted, type in the data that applies to that field.
Note: Edits to the configuration database can be saved after each change in one of two
ways: 1) Press an arrow key and then Enter or Return once; or 2) Press Enter or Return
twice after all selections and entries are made in the screen but before leaving the screen.
If the entries have been accepted, a message "Configuration Successful...
Key To Continue" appears on the screen.
Note: Press CONTROL-A for help information on moving around and editing fields.
1. Use the arrow keys or number keys to select Unit Configuration from the Main Menu. Press
Enter or Return.
2. Use the arrow keys to select DLX Configuration from the Unit Configuration menu. Press
Enter or Return. A DLX Configuration menu is shown in
3. Starting at the top of
4. Assign the selections by pressing Enter or Return.
5. Repeat Steps 3 and 4 for each DLX module installed in the chassis.
Stop! You have completed this procedure.
2-106
© 2000, ADC Telecommunications, Inc.
DLX CONFIGURATION
Table 532-1
and working your way to the bottom, configure the DLX.
Press Any