Avaya S3210R Manual page 9

Message networking help
Table of Contents

Advertisement

Initial LAN administration
The LAN administrator must administer the corporate LAN for the messaging system. Some LANs might be
administered before the on-site installation begins. Other LANs require that the administration for a new server
be done at the time of installation.
Note: Avaya is not responsible for the installation, administration, or test of communications between customer
computers and the LAN.
Site requirements
This section describes physical requirements for the installation site, which include:
Environmental considerations
!
Installation area considerations
!
Weight and space considerations
!
Power requirements
!
The following requirements depend on the Message Networking server being installed at the customer site. See
Identifying the server type and components for details about the different server models.
Environmental requirements
The following table lists the environmental conditions that must be maintained in the area where the system is
installed and maintained.
Operating state
Operating
Non-operating
The following table lists the maximum heat output for each type of server in British thermal units (BTUs).
Server model
S3210R
S3400-H with nonintegrated video
and LAN
S3400-H with integrated video and
LAN
S3210
Server
Temperature
S3210R, S3400-
+10 to +35ºC
H, S3210
(+50 to +95ºF)
S3210R, S3400-
-20 to +50ºC
H, S3210
(-4 to+122ºF)
1123 BTU/hr
682 BTU/hr
1242 BTU/hr
904 BTU/hr
Humidity
(noncondensing)
20 to 80% RH
20 to 90% RH
Maximum heat output
9