Invacare Formula PTO Plus Service Manual page 126

Powered seating on tdx wheelchairs pronto m71 wheelchairs pronto m91 wheelchairs
Hide thumbs Also See for Formula PTO Plus:
Table of Contents

Advertisement

SECTION 17—MK6I ELECTRONICS
2. Remove the half clamps from the armrest.
3. Remove the two mounting screws securing the multiple actuator interface box to the
mounting plate.
4. Remove any tie-wraps (not shown) securing the cable to the powered seating system.
5. Disconnect the network connector. Refer to Connecting/Disconnecting Network
Connectors on page 118.
Installing
1. Secure the multiple actuator interface box to the mounting plate using the two
mounting screws.
2. Tighten the two hex screws to secure the mounting plate to the half clamps and the
half clamps to the armrest.
3. Connect the network connector. Refer to Connecting/Disconnecting Network
Connectors on page 118
4. Secure the cable to the powered seating system using tie-wraps.
5. Test the seating system function to ensure the cable is not pulled, crushed or pinched.
6. If adding the multiple actuator interface box to the seating system, further
programming is necessary to allow the joystick or the 4-way toggle switch to operate
the powered seating functions:
• CALIBRATIONS menu - 4-WAY SWITCH - needs to be set to the desired actuator
controls for each direction.
• POWERED SEATING menu - ACTUATOR CONTROL and ACTUATOR
SELECTION need to be set.
Half Clamp
(Threaded Holes)
FIGURE 17.7 Removing/Installing the Multiple Actuator Interface Box (S4WSB)
Formula
PTO Plus Powered Seating
Armrest
Mounting Screw
Mounting Plate
Network
Connector
(Non-Threaded Holes)
Cable
126
Half Clamp
Hex Screws
Multiple Actuator
Interface Box
Part No 1125031

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents