Beverage / Ice Related Issues - Cornelius ABS 2.0 Service Manual

Automated beverage system
Hide thumbs Also See for ABS 2.0:
Table of Contents

Advertisement

Message
AIR OR CO
LOW OR OUT
2
B
/ I
EVERAGE
CE RELATED
Message
NO ICE DISPENSE
BEVERAGES TOO SWEET
BEVERAGES NOT SWEET
ENOUGH
BEVERAGE NOT COLD
DRINKS FOAMY
© 2019, Cornelius Inc.
Table 26.
Explanation
CO
supply is low or empty or Air com-
2
pressor not operating
I
:
SSUES
Table 27.
Explanation
A. Ice Chute not installed correctly.
B. Bad solenoid valve.
C. Plugged orifice.
D. No / Low CO
.
2
E. No ice in the hopper
A. Carbonator not working.
B. No CO
pressure in carbonator.
2
C. Valve ratio requires adjusting.
D. Plugged filter.
A. Empty B.I.B container.
B. Valve ratio requires adjusting.
A. No ice in hopper.
B. Drains plugged and water standing
on cold plate.
C. Master Cooling system not cooling.
A. Nozzle & Syrup diffuser not clean.
B. Bulk coke tank needs to be
sanitize.
C. Lower or out of CO
D. No jumper transfer hose used on
bulk tank
- 53 -
Change CO
refilled.
Check cause not operating and repair.
Reinstall Ice Chute.
Call for service.
Call for service.
Call for service.
Refill the ice or switch on the ice maker
Call for service.
Call for service.
Call for service.
Replace.
Replace.
Call for service.
Fill ice bin.
Clean ice bin and flush drain with warm
water.
Call for service.
A. Clean and Sanitize.
B. Clean and Sanitize.
C. Replace or Switch to Back Up.
.
2
D. Make sure jumper hose on bulk tank
is connected when changing bulk tanks
ABS 2.0 Service Manual
Correction
cylinder or have bulk tank
2
Correction