Mechanical Issues - Cornelius ABS 2.0 Service Manual

Automated beverage system
Hide thumbs Also See for ABS 2.0:
Table of Contents

Advertisement

ABS 2.0 Service Manual
Message
Low water pressure
NOTE:Contact your local syrup or beverage equipment distributor for additional information and
troubleshooting of beverage system.
M
I
ECHANICAL
SSUES
Message
CLEAR CUP JAM
NO CUP EXTRACTED
TURRET STALLED
CAROUSEL STALLED
Publication Number: 621058590SER
Table 25. (Continued)
Explanation
A. Could be caused by excessively long
runs (over 40 ft.) of 3/8" (9.525 mm)
water supply line.
B. Low water pressure.
C. Plugged water filter.
D. Water booster bladder has burst.
Table 26.
Explanation
Cup(s) is jammed in the carousel at the
cup extraction position and the carousel
and turret are unable to operate.
Cup Tubes.
Loose or missing Hardware.
Cups.
The gripper did not or could not extract
a cup from the cup tube.
No cup present
Grabber Pads.
CO
2
Cup Tubes.
Cups
Turret unable to rotate clockwise of
counter-clockwise.
Carousel Dirty
Cup(s) is jammed in the carousel at the
cup extraction position and the carousel
and turret are unable to operate.Does
the carousel rotate?
A. Increase line size to 1/2".
B. Add water pressure booster pump.
C. Change water filter.
D. Replace water booster tank/bladder.
Remove all cups from the carousel cup
holders at the Extract Position before
pressing the ENTER button. Another
cup will be extracted and dispensing
will continue.
Over stacking of cups in cup tubes. DO
not fill above the top of the cup tube.
Cup tube fingers are damaged (bent),
replace all four fingers.
Cup tubes not properly mounted.
Remove and remount cup tubes.
Check each cup tube to insure all hard-
ware is prese nt on the cup tube .
Replace any missing hardware.
Cups are packed together and will not
separate.
Check cup supply at the extract station
and make sure the cups are not stuck.
Make sure the gripper pads are not
damaged
Refill the cup holders.
Wet, dry off if damaged, replace.
Check bulk CO
back up CO
Cup tube fingers are damaged (bent),
replace all four fingers.
Cups are packed together and will not
separate.
Clear obstruction (cup holder, cup tube
or cup). Press ENTER
clean the Carousel.
Remove all cups from the carousel cup
holders at the EXTRACT POSITION
before pressing the ENTER button.
Another cup will be extracted and dis-
pensing will continue.Make sure carou-
sel is installed correctly. Repair or
Replace.
- 52 -
Correction
Correction
tank, if empty go to
2
and turn on.
2
© 2019, Cornelius Inc.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents