E-Box Configuration - Cornelius ABS 2.0 Service Manual

Automated beverage system
Hide thumbs Also See for ABS 2.0:
Table of Contents

Advertisement

ABS 2.0 Service Manual
!
WARNING:
D
isconnect power to the unit before accessing the
[4] Agitator motor capacitor
[5] 3A-30V
[5] 4A-24V
[5] 4A-12V
[2] 12V DC
POWER SUPPLY
[1] MCB.
[2] 12V DC/ 24V DC power supply.
A. 12V DC - for screen.
B. 24V DC - Power for all sensor.
[3] 30V DC Power supply for Valve bank.
[4] A. Turret motor capacitor.
B. Agitator motor capacitor.
C. Carousel motor capacitor.
[5] Circuit breakers as follows.
C. 4A - 12V DC.
D. 4A - 24V DC.
E. 3A - 30V DC.
[6] AC Power Inlet.
Publication Number: 621058590SER

E-BOX CONFIGURATION

E
-box.
[3] 30V DC Power Supply for Valve Bank.
Figure 2.
[2] 24V DC
POWER SUPPLY
- 6 -
[6] AC Power Inlet
[4] Carousel motor capacitor
[4] Turret motor capacitor
[1]MCB
© 2019, Cornelius Inc.