ROUBLESHOOTING FOR WATER VALVE
If drinks overfill, this means the dispense times are too high for the flow rate that the valves have been adjusted to.
Repeat the above steps and increase volume entered. This will shorten the dispense time prevent overfilling.
If drinks underfill, this means the dispense times are too low for the flow rate that the valves have been adjusted to.
Repeat the above steps and decrease volume entered. This will lengthen the dispense time prevent underfilling
A
S
DJUST THE
YRUP
After the water flow rates are set, the syrup ratio must be adjusted. The water flow rates were set to a target flow rate
of 3.0 oz/sec(88.72 ml/sec) and now the syrup flow rates must set to achieve the correct ratio required for each brand. To
check the ratio required, select the brand on the right screen and set the valve according to the ratio displayed.
NOTE: Always adjust the ratio for the syrup with the highest viscosity first. Some syrups may be too viscous and
you might be unable to achieve the desired ratio. In these cases, the PW or CW flow rate will have to be
lowered to permit setting the proper ratio.
NOTE: Once the PW and CW flow rates are set they should not be changed. Any change to the PW or CW will
require that all syrup to water ratios be readjusted.
NOTE: Be sure to use the correct ratio cup for the ratio being adjusted.