ABS 2.0 Service Manual

U.S.A. Follow The Procedure Below:

1. Hold the ratio cup water compartment below the valve and select the Plain Water button if adjusting a non-car-
bonated drink or the carbonated water button if adjusting a carbonated water drink.
2. Hold the appropriate ratio cup syrup compartment below the valve.Select the syrup brand and press the "4
SECOND DISPENSE".
3. Acceptable ratio is shown in the illustration below as the Correct Reading within the same bandwidth.

Australia Follow The Procedure Below:

1. Using the table below, determine the volume of syrup that should dispense in the 4 second pour.
Example: The ratio for the brand is 5.25, and it is a carbonated (CW) drink, the unit should dispense 75.7 ml of
syrup in the 4 second dispense. If the ratio for the brand is 5.25, and it is plain water (PW) drink, the unit should
dispense 66.3 ml of syrup in the 4 second dispense.
Ratio
5.25/1
5.25/1
4.75/1
4.75/1
4.25/1
4.25/1
9.5/1
2. Hold the volume measuring device below the valve, Select the syrup brand and press the "4 SECOND DIS-
PENSE".
3. Adjust the flow regulator as required.
See Figure 51 for location of the adjustment screws on the valve.
At the end of this adjustment press the HOME button twice to return to the main menu.
Publication Number: 621058590SER
Figure 57. Ratio Cup, Acceptable Ratio
Table 16.
CW/PW
CW
PW
CW
PW
CW
PW
PW
- 30 -
ml Syrup
75.700
66.300
82.300
72.000
90.100
78.900
39.500