IDC 255 Progate Drive Thru Service Manual
B
N
D
EVERAGE
OT

BEVERAGE NOT DISPENSING

Is the key switch
on/off
Off
1. Check the key switch
Publication Number: 621057419SER
ISPENSING
Is
there power on
On
the line side of the
transformer
No
1. Check the transformer connections
to the E-Board in the E-Box.
2. Check the E - Board in the E- Box
ensuring that power is being
supplied to the board.
Is
there power on the
Yes
load side of the
transformer
No
1. Check the transformer.
2. Change the transformer.
1. Check the wire harness from the beverage
valves to the terminal board.
2. Check the beverage dispense valve to ensure
that they are functioning.
3. Change beverage valve.
4. Check the water line to the valve and the syrup
line to the valve.