Download Print this page
Cornelius ABS 2.0 Quick Start Manual
Hide thumbs Also See for ABS 2.0:

Advertisement

Quick Links

ABS 2.0 Operator's Manual
CLEANING / MAINTENANCE PROCEDURES
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user.
Verify all power is off to the unit before performing any work
Failure to comply could result in serious injury, death or damage to the equipment.
!
CAUTION:
Do not use metal scrapers, sharp objects or abrasives on the ice storage hopper, top cover, agitator disc or
exterior surfaces. Do not use solvents or other cleaning agents as they may attack the material resulting in
damage to the unit
Soap solution – Use a mixture of mild detergent & warm (100°F) potable water.
Sanitizing Solution – Dissolve 1 packet [1oz. (29.6 ml)] of Kay - 5 or Stera Sheen Green Label into 2.5 gallons (9.46
L) of warm [80 - 100°F (26.7 - 37.8°C)] potable water to ensure 100 ppm of chlorine.
D
C
AILY
LEANING AND
1. Check the temperature, smell, and taste of the product.
2. Check the water pressure coming to the unit using a pressure gauge on the back room package, it
should be same as mentioned in Table 3 on page 6.
3. Check carbonation of the drink visually or by tasting.
4. Using a pressure gauge check the inlet pressure CO
mentioned in Table 3 on page 6 .
5. Check the date on all of the BIB's (bags in boxes).
Locate Required Tools
Soap Solution
Paper Towel
Clean Cloth
Carbonated Water
Sanitizing Solution
Sanitizing Bucket
Clean Sanitized Cloth
Publication Number: 621058590OPR
S
ANITATION
or air supply to the system, it should be same as
2
- 12 -
© 2019, Cornelius Inc.

Advertisement

loading

Summary of Contents for Cornelius ABS 2.0

  • Page 1 ABS 2.0 Operator’s Manual CLEANING / MAINTENANCE PROCEDURES WARNING: Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work Failure to comply could result in serious injury, death or damage to the equipment.
  • Page 2 ABS 2.0 Operator’s Manual STAGING CLEANING Dis-assemble Staging 1. Unscrew the 3 thumb screws holding the screw in place as shown in Figure Figure 11. and remove the cover. Figure 11. 2. Remove the conveyor by lifting it up as shown in Figure Figure 12.
  • Page 3 ABS 2.0 Operator’s Manual Clean Drip-Tray Area 1. Make sure water deflector is properly installed, this will help prevent motor failures. (Order replacement if the deflector is missing) as shown in Figure Figure 14. Figure 14. Drain line 2. Pour warm (NOT HOT) water down the drip-tray drain.
  • Page 4 ABS 2.0 Operator’s Manual 4. Wipe down drip-tray and splash panel with a clean cloth to remove any soapy residue as shown in Figure Figure 17. Figure 17. 5. Spray Sanitizing Solution all around drip-tray and splash panel. Let air dry for 5 minutes.