Connecting the Air Supply Lines to the UniDrum
Perform the following procedure to connect the input
air supply lines to the UniDrum Supply System.
Connecting Air Supply Lines to the Supply
Units
To connect the main air supply line to the LH and RH
Supply Units (A, B), perform the following steps:
To reduce the risk of overpressurizing your system,
which could result in component rupture and cause
serious injury due to splashing and skin injection,
never exceed the specified maximum incoming air
pressure to the Pumps (see the Technical
Specifications on page 77).
TI0198
Air Line to Pump Air Manifold
F
. 5
IG
309169ZAF
Main Air Inlet
Main Air Shutoff Valve (supplied by the customer)
Air Line to Pneumatic Panel
Main Air Filter
Pilot Valves
(models 246983 and 246984 do not have "Y" manifold outlets)
Have a qualified technician connect both Supply Units
to an air supply source that has the following required
ratings:
Description
Inlet Port Size:
Air Volume:
Input Air:
1. Check the air supply to ensure that it is properly
sized and pressure-rated for this system.
2. Connect the air supply line to the 1 in. npt Main Air
Inlet (E).
Runaway Valve
Material Outlets
Installation
Requirements
1 in. npt(f)
450 cfm (maximum)
80 psi (5.5 bar, 0.55 MPa)
AirLine Lubricator
17