Technology Module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
Manual, 05/2019, A5E35061186-AB
Meaning
Value below low limit of the parameter "Period
duration"
"Dithering" activated, although "Pulse width
modulation PWM" mode is not configured
"High-speed output (0.1 A)" enabled in the
"PWM with DC motor" mode or in one-channel
operation
"Current control" activated, even though "Pulse
width modulation PWM" mode is not configured
"High-speed output (0.1 A)" and "Current con-
trol" enabled in "Pulse width modulation PWM"
mode
"HW enable" for DIn.0 configured in "On/Off
delay" mode
Manipulated value low limit >= Manipulated
value high limit
Dithering period duration < 4 × PWM period
duration
Dithering period duration < 2 ms
"1" is configured for both substitute values
(DQn.A and DQn.B).
Reserved bit is not set to 0.
Parameter data record
A.2 Parameter validation errors
Solution
Without High-speed output: Enter a parameter value
of at least 100
.
D
With high-speed output: Enter a parameter value of at
least 10
.
D
Disable "Dithering"
Disable "High-speed output (0.1 A)"
Deactivate "Current control"
Disable "High-speed output (0.1 A)" or "Current con-
trol"
In the "On/Off delay" mode, do not configure "HW
enable"
Manipulated value low limit < Manipulated value high
limit
Dithering period duration >= 4 × PWM period
duration
Dithering period duration > 2 ms
Only configure "1" for DQn.A or DQn.B.
Set reserved bit to 0.