4.10

Handling of the SLOT parameters

In addition to the main setpoint OUTPUT_VALUE, you can change a setpoint for another
parameter.
You specify the load value with the SLOT value in the control interface. You use the
LD_SLOT load request to specify the meaning of the value in SLOT depending on the
operating mode:
LD_SLOT
In so doing, you use the MODE_SLOT control bit to choose whether you want to apply a
change of the respective value once or cyclically.
Technology Module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
Manual, 05/2019, A5E35061186-AB
Meaning of the value in
SLOT
0
No action, idle
D
1
Period duration
D
2
On delay
D
3
Off delay
D
4
Duty cycle
D
5
Dithering ramp up,
D
ramp down
6
Dithering amplitude
D
7
Dithering period duration
D
4.10 Handling of the SLOT parameters
Operating modes for use of the value
All operating modes
Pulse width modulation PWM
Pulse train
PWM with DC motor
Pulse output
Pulse width modulation PWM
Pulse train
Frequency output
PWM with DC motor
On/Off delay
Pulse train
Pulse width modulation PWM
Pulse width modulation PWM
Pulse width modulation PWM
Configuring/address space
Data type of
SLOT
UDINT
2 × INT
UDINT
139