Installing Avaya Secure Router 2330/4134 hardware components
9. Enter the following command to set the replacement module to an active state: no
10. To verify the module status, enter: show chassis
If you encounter issues initializing the replacement interface module, see Avaya Secure Router
2330/4134 — Troubleshooting (NN47263–700).
Connecting Secure Router 2330/4134 power cables
There are two types of power supply modules available for the Secure Router 4134:
• AC power supply module (standard or PoE) requiring an external AC power source
• DC power supply module requiring an external DC power source
On the Secure Router 2330, the internal power supply is AC only.
Use the procedures in this section to connect AC power cables to a Secure Router 2330 or
4134, or DC power cables to a Secure Router 4134.
Connecting AC power cables
Average time to install one AC power cable: 1 minute.
Electrostatic alert:
ESD
Always wear an ESD-preventative wrist strap when connecting cables or performing
maintenance on a Secure Router 2330/4134. Ensure that the wrist strap makes contact with
your skin.
Prerequisites
• Ensure you have one or two appropriately rated AC power cords, dependent on your
configuration.
• Ensure the power cord or cords are long enough that you can plug the male end into a
standard 110/220 V AC power outlet.
Procedure steps
1. Insert the female end of an appropriately rated AC power cord in the AC receptacle
62
Installation — Hardware Components
shutdown
on the rear panel of the Secure Router 2330/4134, as shown in the following
figure.
Comments? infodev@avaya.com
August 2013