CHAPTER 4: Installing the Gateway
Installation Guidelines
Tools and Parts Required
Installing the Gateway in a Rack
32
Rack-Mounted Installation
Warning: Do not install more than three gateways adjacently in the same rack. This avoids
excessive pre-heating of the air flowing through the heatsinks of the upper units by the unit
directly below them.
Warning: Do not place a gateway between two gateways deeper than 23 cms. This avoids
formation of hot air traps around the rear heatsink of the gateway.
To install the gateway in a rack, you need the following tools:
Screws—Use screws that are compatible with the equipment rack
An appropriate screwdriver
To install the gateway in the rack (see Figure 18 on page 32):
1.
Lift the gateway and position it in the rack.
2.
Ensure that the holes of the mounting brackets align evenly with the holes of the equipment
rack on both sides.
3.
Place the screws in the holes of the equipment rack, and secure them using an appropriate
screwdriver.
Figure 18: Rack-Mounting the Gateway