Physical Specifications
Gateway Environmental Specifications
Advanced Clocking Module Specifications
Table 22 on page 75 summarizes the physical specifications for the gateway chassis.
Table 22: Physical Specifications
Description
Chassis dimensions
Power supply
Weight: DC model
Chassis with single power supply, fully configured
Chassis with dual power supply, fully configured
Weight: AC model
Chassis with single power supply, fully configured
Chassis with dual power supply, fully configured
Table 23 on page 75 specifies the environmental specifications required for the gateway operation.
In addition, the site should be as dust-free as possible.
Table 23: Gateway Environmental Specifications
Description
Relative humidity
Temperature
Seismic
Note: Install the gateway only in restricted or service areas, such as dedicated equipment rooms
and equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National
Electrical Code, ANSI/NFPA 70.
Table 24 on page 75 lists the advanced clocking module specifications.
Table 24: Advanced Clocking Module Specifications
Advanced Clocking Module
Dimensions (H X W X D)
Weight
Value
2.6 in. (6.7 cm) high
17.51 in. (44.47 cm) wide
9.44 in. (23.97 cm) deep
Weight: AC power supply
0.93 lb (0.42 kg)
Weight: DC power supply
0.71 lb (0.32 kg)
12.23 lb (5.54 kg)
12.94 lb (5.87 kg)
12.45 lb (5.65 kg)
13.38 lb (6.07 kg)
Value
Normal operation ensured in relative humidity
range of 5% to 95%, noncondensing
Normal operation ensured in the following
temperature range:
DC Hardened: –40° to 158° F (–40° to 70° C)
DC Non-hardened: 23° to 131° F (–5° to 55° C)
AC: 23° to 131° F (–5° to 55° C)
Designed to meet Telcordia Technologies Zone 4
earthquake requirements
Description
150mm X 80mm X 26mm
1.014 lb (0.45 Kg)
:
Physical Specifications
75