CHAPTER 10: Replacing Hardware Components

Installing a DC Power Cable

Replacing the Fuse

64

Replacing the Fuse

1.
Switch off the customer site circuit breakers. Follow your site's safety and ESD procedures.
2.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no
chance that the cables might become active during the removal process.
3.
Remove the power cable from the DC power source.
4.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the
strap to the ESD point on the chassis. For more information about ESD, see "Preventing
Electrostatic Discharge Damage" on page 83.
5.
Remove the screws from the terminal studs.
6.
Remove the cable lug from the terminal studs.
7.
Carefully move the power cable out of the way.
To install a replacement power cable for a DC power supply:
1.
Locate a replacement power cable that meets the specifications defined in "DC Power Cable
Specifications" on page 78.
2.
Verify that a licensed electrician has attached a cable lug to the replacement power cable.
3.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no
chance that the cables might become active during the removal process.
4.
Secure the power cable lug to the terminal studs.
5.
Make sure the cable is not touching or in the way of the gateway, and that it does not drape
where people could trip on it.
6.
Attach the power cable to the DC power source.
7.
Switch on the customer site circuit breaker.
8.
Verify that the system LED is lit green steadily indicating that the power cable is correctly
installed and the power supply is functioning normally.
9.
Repeat Steps 2 through 6 to install another DC power cable.
Note: AC power supply assembly includes a second fuse in series with Neutral, which is not user
replaceable.
Note: Ensure that you use a time lag fuse of type 5 X 20 mm, rated at 1.25 A, 250v is used in the
gateway.
To replace the fuse (see Figure 27 on page 65):
1.
Locate a replacement fuse appropriate for your power supply.
2.
Unplug the power cord from the power supply receptacle for which the fuse has to be
replaced.
3.
Unplug the other end of the power cord from the power source.
4.
Loosen the fuse holder from the power supply and pull out the fuse from the holder.