Technical Data; Control Unit Snd40 - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
9

Technical data

Pos: 68 /Sc hweis snaht/ Geräte/ SN D40/2 Te chni sche Daten/ SND 40 Tec hnis che Da ten @ 0\mo d_11 285 825 2007 8_5 01.do cx @ 70 9 @ 2 @ 1
9.1

Control unit SND40

Mains voltage:
Power consumption:
Switch-on current:
External fuse protection:
Weight:
Dimensions of industrial enclosure (L x W x H)* :
Protection class of industrial enclosure:
Ambient temperature:
Further characteristics:
• Embedded PC with Windows CE operating system for user interface
• Real-time computer (ARM7) for detection and positioning
• Programming and operation via 10" Touchscreen
• 31 programs, selectable via parallel interface / field bus interface
• 8 potential free optocoupler inputs 24 V DC with common ground potential; sinking inputs.
Specification:
− min. switching voltage HIGH:
− max. switching voltage HIGH:
− min. switching voltage LOW:
− max. switching voltage LOW:
• 8 potential free optocoupler outputs with common positive foreign supply
13... 30 V DC; sourcing outputs.
Specification:
− max. switched voltage:
− max. switched current:
− max. contact rating:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Technical Data
Note!
For inductive load a coil protection diode is to be used. Otherwise the signal output
can be destroyed by the overvoltage when switching the inductive load off.
Manual
85...264 VAC
<110 W
<15 A/115V, <30 A / 230V
3.15 A medium-blow
12 kg (26.5 lbs.)
approx. 420 x 234 x 305 mm
*approx. 435 x 234 x 305 mm (starting May 2016)
IP54
0 - 40 °C (operation)
13 V DC
30 V DC
0 V DC
4 V DC
30 V DC
50 mA (internal current limitation)
1.5 W (only resistive load)
Technical data
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents