8) Inspect Magnetic Switch
Push in plunger and release it. The plunger
should return quickly to its original position.
Replace if necessary.
Fig. 925
Pull-in coil open circuit test
Check for continuity across magnetic switch
exists, the coil is open and should be replaced.
Fig. 926
9-10
Hold in coil open circuit test
Check for continuity across magnetic switch 'S'
terminal and coil case. If no continuity exists,
the coil is open and should be replaced.
Fig. 927
REASSEMBLY
Reverse disassembly procedure, using care on
following points.
When installing pinion drive lever, refer to
l
Fig. g-2 for its installation direction.
brush position.
3
1. Brush holder
3. Brush positions
2. Yoke
Fig. 9-27- 1