Configuration Utility presented on the Disk page. LUN expansion may occur in Disk Arrays where
space is available. If insufficient space is available, additional physical disks may be added to the
array dynamically.
Figure 17 Expanding a LUN (Smart Array only)
To extend a LUN where space is available in the array (Smart Array only):
1.
Click the Disks tab.
2.
Click Array Management.
3.
Click Array Configuration Utility, and then log in.
4.
Select the appropriate array controller and the appropriate array that the logical drive is contained in.
5.
Select the appropriate logical drive.
6.
Click Extend Size.
7.
Enter the total size of the logical drive in MB (not just the amount to be added), and then click OK.
8.
Click Save to update the configuration.
9.
Close the ACU.
To extend a LUN where space is not available in the array (Smart Array only):
1.
Add an unassigned physical disk to the array using the ACU. If an unassigned physical disk is
unavailable, add a new disk to the appropriate storage device, and then select Refresh.
2.
To add an unassigned physical disk to the array use the following steps:
a.
Select the appropriate array controller and the appropriate array that the logical
drive is contained in.
b.
Select Expand Array.