Siemens SIPART PS2 Operating Instructions Manual page 350

Electropneumatic positioner with profibus pa
Hide thumbs Also See for SIPART PS2:
Table of Contents

Advertisement

Booster
E.9 Technical specifications of booster
Booster
● Storage
● Transport
Weight booster, single-acting
● Booster, single-acting, polycarbonate, with positioner
● Booster, single-acting, polycarbonate, installation kit only
● Booster, single-acting with flameproof enclosure, with
positioner
● Booster, single-acting with flameproof enclosure,
installation kit only
Weight booster, double-acting
● Polycarbonate enclosure, with positioner
● Polycarbonate enclosure, installation kit only
● Enclosure with flameproof enclosure, with positioner
● Enclosure with flameproof enclosure, installation kit only
Connections
● Pneumatic
● Manometer
Auxiliary power (air supply)
● Pressure
● Supply air
● Air consumption
Manometer
Flow capacity
350
1K5, but -40 ... +80°C (1K5, but -40 ... +176°F)
2K4, but -40 ... +80°C (2K4, but -40 ... +176°F)
4.0 kg (8.8 lb)
2.9 kg (6.5 lb)
7.9 kg (17.4 lb)
3.3 kg (7.3 lb)
5.3 kg (11.7 lb)
4.3 kg (9.4 lb)
9.3 kg (20.5 lb)
4.7 kg (10.4 lb)
1/2-14 NPT or G½
1/4-18 NPT or G1/8
Compressed air, carbon dioxide (CO2), nitrogen (N), noble
gases or cleaned natural gas
1.4 ... 7 bar (20.3 ... 101.5 psi)
According to ISO 8573-1
1.2 x 10
Nm
/h (0.007SCFM)
-2
3
Thread 1/4-18 NPT or G½ with stainless steel enclosure
MPa, bar, psi
Degree of protection IP66
Cv 2.0
Operating Instructions, 05/2019, A5E00127926-AC