Ground and AC Voltage Check
Before installing the 3001 Copier,
check for correct voltage, polarity and
the grounding of the AC outlet
provided by the customer. Use the
Polarity Checker (600T467) or a multi
meter. Incorrect voltage applied to
the 3001 could result in poor
performance or damage t o the copier.
Q
(USO) and (XLA 60Hz): The power
line outlet must be a 15
-
20 amp
single dedicated line (wired directly
t o the circuit breaker panel) with no
shared neutral and on a different
phase from the lighting circuits. A 20
amp line and duplex outlet are
preferred because they will allow an
available cutter accessory t o be
installed with no change to the
electrical service.
If specifications are not met, the AC
outlet is wired or grounded
incorrectly. Inform the Customer and
request that a licensed electrician
correct the problem. DO NOTmake
the correction yourself.
THE APPLIANCE COUPLER (POWER SUPPLY
CORD) IS THE DISCONNECT DEVICE FORTHIS
EQUIPMENT. ENSURE THAT THE
INSTALLATION IS NEARTHE OUTLET AND IS
EASILY ACCESSIBLE.
NOTES:
When installing
a
(USO)
or (XLA
60
Hz)
configuration 3001 Copier, one 1 15
VAC outlet is required at the customer
site.
When installing a (XLA 50 Hz)
configuration 3001 Copier with a cut
sheet feeder accessory, two 220 VAC
outlets are requiredat the customer
site. The 3001 Copier requires a
separate power lines.
When installing a (XLA 50 Hz)
configuration 300 1 Copier with a
cutter accessory, three 220 VAC outlets
are required at the customer site. The
3001 Copier requires a single
dedicated power line. The cutter
accessory may share a power line.
1. (FIGURE1 CHECKTHEGROUNDAND
THE AC VALTAGE (USO), (XLA 6OHz).
Neutral
15 Amp
(ACN)
60053704
(White
Hot
Wire)
( A W
(Black
Wire)
Ground
NEMA=
(Green
5-1 5 R
Wire)
Neutral
20 Amp
(ACN)
600S3703
~ o t
(white
Wire)
NEMA
5-20R
( A W
-m
(Black
Wire)
Ground
,
-
(Green
Wire)
Preferred
Figure
1.
Check the Ground and the AC
Voltage
(USO),
(XLA 60Hz)
A. Check for
1 15
VAC between AC Hot and
AC neutral.
B. Check for 1 15 VAC between AC Hot and
ground.
C. Check for less than 2 VAC between AC
neutral and ground.
3001 Installation