REP 9.1 1 CONTAMINATION
SEAL
PARTS LIST ON PL 9.3
REMOVAL
1.
WARNING: DISCONNECT THE POWER
CORD.
2 . REMOVE THE SEPARATOR GUIDES, THE
RIGHT SIDE COVER, AND THE LEFT SIDE
COVER.
3. REMOVE THE XEROGRAPHIC MODULE
(REP 9.1).
4.
REMOVE THE PHOTORECEPTOR DRUM
ASSEMBLY (REP 9.2).
5.
REMOVE THE CLEANING BLADE
ASSEMBLY (REP 9.4, STEPS 1
-
4)
6.
REMOVE THE CHARGEIPRECHARGE
COROTRON.
7. REMOVE THE CONTAMINATION SEAL.
8. VACUUM THE CLEANING AUGER AND
THE AREA WHERE THE SEAL WILL BE
INSTALLED.
REPLACEMENT.
1. (FIGURE 1): PLACE THE NEW
CONTAMINATION SEAL IN THE
XEROGRAPHIC MODULE.
Q
STEP
28:
Ensure that the seal stays
against side of the xerographic module.
2.
(FIGURE 2): INSTALL THE CONTAMINATION
SEAL.
u
PLACE THE SEAL IN
THE MODULE AND
AGAINST THE SIDE OF
THE MODULE
ADHESIVE
OFF
REMAINING FROM
THE DAMAGED
Figure 1. Install the Contamination Seal
ALIGN THE EDGE OF THE
A
SEAL WITH THE EDGE OF
REMOVE
3
INCHES
THE SEAL
THROUGH C UNTIL THE SEAL
IS COMPLETELY INSTALLED
I * ]
Figure 2. Install the Contamination Seal
REP 9.1 1