Fault messages & troubleshooting

14.4.4 Core temperature sensor defective (699, 700)

Description
The core temperature function is no longer available.
Troubleshooting
Is the wire or the test prod damaged physically?
Remove existing core temperature sensor from the control board A1, X24 and
plug in new core temperature sensor. Error eliminated?
No
Yes
Replace control board.
Replace core temperature sensor.