11.2 CO2 setting
11.2.1 Opening the Setting menu
DANGER
WARNING
INFORMATION
Prerequisite Gas connection line connected
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
Risk of poisoning from exhaust gases
• Ensure that exhaust gases are discharged properly and that the necessary
amount of combustion air is supplied.
• Ensure that a maximum CO content of < 0.1 vol. % or < 1000 ppm is
achieved in undiluted exhaust gas.
Some measurements on the unit require it to be at opeating temperature.
• The operating temperature is reached when the temperature in the cooking
chamber is between 130 °C —180 °C.
Checked for leaktightness outside the unit
Connection pressure checked
Checked for leaktightness inside the unit
Left side wall removed
1. Check the rated heat input at maximum output.
2. Check the rated heat input at minimum output.
3. Check the primary air quantity.
4. Check the exhaust gas values.
Preparations
1. Switch on the unit.
2. Tap the "Unit functions" button.
The Unit functions menu is displayed.
3. Tap the "Settings" field.
The PIN window opens.
4. Enter password "999".
5. Tap the Confirm button.
The CO2 setting appears.
As an alternative, access is possible via the service menu.
Service instructions
Gas technology
69