Fault messages & troubleshooting
14 Fault messages & troubleshooting

14.1 Overview

No.
Fault message displayed
694
Cooking sensor defective
695
696
Top cooking chamber sensor defective
728
697
Bottom cooking chamber sensor defective
729
699
Core temperature sensor defective
700
701
Fan defective. Cooking program was canceled
702
Fan defective or temperature limiter triggered
703
Top fan defective. Automatic switching to
emergency operation
705
704
Bottom fan defective. Automatic switching to
emergency operation
706
709
Water pressure too low
Water pressure during WaveClean too low
710
Vapour sensor defective
714
Internal core temperature sensor defective
716
715
External core temperature sensor defective
717
5007
Not enough storage space for software update
5008
No new version found
5009
The application could not be started. Application
is restarting.
5010
The application could not be started. Restore
configuration backup?
5013
Application could not be restored! Restore to
factory settings with OK.
FAN_ID23
Fan error: Attempt to restart
84
Section
(see „14.4.1 Cooking chamber sensor defective
(694, 695)‟, Page 88)
(see „14.4.2 Top cooking chamber sensor
defective (696, 728)‟, Page 89)
(see „14.4.3 Bottom cooking chamber sensor
defective (697, 729) ‟, Page 90)
(see „14.4.4 Core temperature sensor defective
(699, 700)‟, Page 91)
(see „14.5.3 Fan defective. Cooking program was
cancelled (701)‟, Page 100)
(see „14.5.2 Fan defective or temperature limiter
triggered (702)‟, Page 98)
(see „14.5.4 Top fan defective. Automatic
switching to emergency operation (703, 705) ‟,
Page 100)
(see „14.5.5 Bottom fan defective. Automatic
switching to emergency operation (704, 706)‟,
Page 101)
(see „14.6.1 Water pressure too low (709)‟, Page
105)
(see „14.4.7 Water vapor sensor defective (710)‟,
Page 93)
(see „14.4.5 Internal core temperature sensor
defective (714, 716)‟, Page 92)
(see „14.4.6 External core temperature sensor
defective (715, 717)‟, Page 92)
(see „14.7.5 5007: Not enough storage space for
software update‟, Page 110)
(see „14.7.6 5008: No new version found‟, Page
110)
(see „14.7.7 5009: The application could not be
started. Application is restarting.‟, Page 111)
(see „14.7.8 5010: The application could not be
started. Restore configuration backup?‟, Page
111)
(see „14.7.9 5013: Application could not be
restored! Restore to factory settings with OK.‟,
Page 111)
(see „14.5.6 FAN_ID23: Fan error: Attempt to
restart‟, Page 103)
Service instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents