14.8.6 No flame (bottom)(OTH_ID6)

Description This error message only appears if on the first gas request on

14.8.7 Communication fault between I/O and ignition electronics (OTH_ID25)

Replace CAN bus cable between control board, connector X4 and ignition electronics. Error
The fault message refers to the upper burner on 215 and 220
pedestal units.
Troubleshooting
Further fault message as for error message No gas
Troubleshooting‟, Page
Description
program start the flame was detected (response from ionization
electrode present) and then was lost (no response from the ionization
electrode).
The error message refers to the lower burner on 215 and 220
pedestal units.
Troubleshooting
Further fault message as for error message No gas
Troubleshooting‟, Page
Description
There is a communication fault between the control board and ignition
electronics.
Troubleshooting
eliminated?
No
Replace ignition electronics. Error eliminated?
No
Replace control board.
Service instructions
Fault messages & troubleshooting